Add to Cart
2 Alarm Relays Peracetic Acid Analyzer Standard Modbus For Industrial Cooling Water
Product Introduction
Peracetic acid (C2H4O3) is a bright, colorless liquid that has a piercing odor and a low pH value. Peracetic acid is produced by a reaction between hydrogen peroxide and acetic acid. The DRFN’s peracetic acid analyzer ADS2-U3-P9.2 offers ease of use, accuracy and reliability for the monitoring and control of peracetic acid in water. The PAA analyzer consists of a transmitter and a peracetic acid probe.
Features Of The Transmitter
>> The peracetic acid controller is equipped with 2 settable 0/4~20mA active current loop outputs;
>> The standard configuration of the PAA transmitter is 2 settable SPST alarm relays;
>> Time and historical data recording functions to meet the user’s higher data management requirements;
>> Provide 100~240V AC or 18~36V DC power supply mode, both of which are wide-voltage power supply;
>> The communication standard is equipped with a two-wire RS485 interface, the communication protocol is MODBUS RTU;
Parameters Of Peracetic Acid Analyzer
Product Name | Peracetic Acid Analyzer |
Product Model | ADS2-U3-P9.2 |
Software Version | DRFN peracetic acid Analysis software V1.0 |
Display Range | 0.00~200.00mg/L |
Resolution | 0.001mg/L |
Accuracy | Better than 0.15% of the measuring range |
Stability | 0.05% of the measuring range every 24 hours, no accumulation |
Repeatability | Better than 0.1% of the measuring range |
Relay Control | 2 settable SPST relays, the max. load 3A/250VAC |
Sensor Self-diagnosis | screen image and buzzer prompt |
Analog Current Output | 2 settable 0/4~20mA active current loop output max. load 1000Ω |
Communication Method | MODBUS RTU; support JSON text data format |
Display Screen | 128*64 LCD |
Time History/Data Record | Year/month/day/hour/min/second, record 14000 historical data |
Protection Grade | IP66 |
Operating Environment | 0~60℃, relative humidity less than 95% |
Storage Environment | -20~70℃, relative humidity less than 55% |
Shell Material | Enhanced ABS |
Dimensions | 144*144*120mm (hole size 138*138 mm) |
Mounting Method | Wall mounting, pipe clamping, panel installation |
Power Supply | 18~36V DC or 100~240V AC |
Weight | 800g |
Power Consumption | 12W |
Matching Peracetic Acid Sensor Parameters
Type | Measuring range: ppm | Resolution: ppm | Output signal | Power supply | Item number |
P9.2-MA-200 | 0~200 | 0.1 | 4~20 mA | 12~30 VDC RL :50Ω~900Ω | 3426100 |
P9.2-MA-2000 | 0~2000 | 1 | 3426101 | ||
P9.2-MA-2% | 0~2 % (20000 ) | 0.001 % (10) | 3426102 | ||
P9.2-MA-200-M12 | 0~200 | 0.1 | 4~20 mA | 12~30 VDC RL:50Ω~900Ω | 3426100 |
P9.2-MA-2000-M12 | 0~2000 | 1 | 3426101 | ||
P9.2-MA-2%-M12 | 0~2 % (20000 ) | 0.001 % (10) | 3426102 |