Suzhou Delfino Environmental Technology Co., Ltd.

Create value for customers!

Manufacturer from China
Verified Supplier
4 Years
Home / Products / pH ORP Sensor /

Online Pps Material PH Probe With High Temperature Resistant For Waste Water

China Online Pps Material PH Probe With High Temperature Resistant For Waste Water wholesale
  • China Online Pps Material PH Probe With High Temperature Resistant For Waste Water wholesale
  • China Online Pps Material PH Probe With High Temperature Resistant For Waste Water wholesale
  • China Online Pps Material PH Probe With High Temperature Resistant For Waste Water wholesale

Online Pps Material PH Probe With High Temperature Resistant For Waste Water

Ask Latest Price
Brand Name :Daruifuno
Model Number :ASP400-VYD05
Certification :CE
Place of Origin :China
MOQ :1
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :10000 Sets per Month
Delivery Time :5-25 days
Packaging Details :Carton
Product Name :PH sensor
Model :ASP 400-VYD05
PH :0~14pH
Materials in contact with liquid :PPS+Glass+Teflong
Working Pressure :0~6Bar
Working Temperature :0.0~100.0℃
Reference reference electrode :Ag/AgCl
Reference System :Double salt bridge
Temp. Unit :Vacant
Cleaning :Cleaning interface(Optional)
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Online Pps Material PH Probe With High Temperature Resistant For Waste Water

Signal output: RS-485 (Modbus protocol). Used for environmental water quality monitoring, acid/alkali/salt solution, chemical reaction process and industrial production process, it can meet the requirements of online pH measurement for most industrial applications.

Specification:

Modle
ASP 400-VYD05
PH Range
0~14pH 0.01pH
Shaft Material
PPS
Working TEMP
0~100℃
Reference System
double salt bridge
Reference Electrode
Ag/AgCl
Electrolyte
Crystal
Working Pressure
0~6Bar
Temperature Unit
Vacant
Membrane
Porous Teflon
Glass Head

Transparent low impedance

Dimension
Diameter: 35mm Length: 260 mm ( include the cleaning cover)
Thread Size
1 inch NTP(both ends)
Lead Wire
Standard 5m
Ground
--
Cleaning
A protective cover with its own cleaning interface(Optional)
Application
Sewage

Please click the pH sensor user manual here:

ASP400T pH sensor technical data.pdf

Brief introduction:

◆ pH composite electrode, the body adopts high-performance ABS plastic shell encapsulation
◆ Sturdy structure, with installation threads at the beginning and end, easy to install;
◆ The electrode is equipped with a protective cover with its own cleaning interface;
◆ The indicator electrode adopts a low-impedance hemispherical glass head, which has high strength and is not easily broken;
◆ The reference adopts a large-area annular porous Teflon membrane, which has fast penetration speed, fast response, not easy to block, and easy to clean;
◆ The reference system is designed with double salt bridge, the reference electrode is Ag/AgCl, and the reference is filled with saturated KCL+excess KCL crystal;

Online Pps Material PH Probe With High Temperature Resistant For Waste Water

Aplication:

Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

FAQ

1. What is themeasurement principle of this pH electrode?
A:
The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


2. How is this glass pH electrode composed?
A:
The pH electrode is usually composed of an indicator electrode and a reference electrode.


3. How to judge the pH of the solution?
A:
If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than


4. What is the wire length of the pH electrode?
A: The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

5. How often must the pH sensor be calibrated?
A: Depends on the type of sample:
Dirty samples and non-aqueous samples require more frequent calibration.
Depends on the required accuracy:
For very accurate measurements, at least daily calibration is required.
Depends on the quality of the electrode:
Old electrodes require more frequent calibration.

6: What's your business range?
A: We manufacture Water quality analysis. The monitoring parameters of our water quality analyzer main include: PH, ORP, dissolved oxygen, conductivity/TDS/salinity, turbidity, SS, Chlorophyll, Blue-green algae, COD, NH4-N and so on.

7: May I visit your factory?
A: Of course, our factory is located in suzhou city , welcome your arrival.

China Online Pps Material PH Probe With High Temperature Resistant For Waste Water for sale

Online Pps Material PH Probe With High Temperature Resistant For Waste Water

Inquiry Cart 0