Suzhou Delfino Environmental Technology Co., Ltd.

Create value for customers!

Manufacturer from China
Verified Supplier
5 Years
Home / Products / pH ORP Sensor /

Protection Bottle Glass PH Electrode 0~80℃ Temp. Resistance For Dirty Water

Contact Now
Suzhou Delfino Environmental Technology Co., Ltd.
Visit Website
City:suzhou
Province/State:jiangsu
Country/Region:china
Contact Person:MsYuki Fu
Contact Now

Protection Bottle Glass PH Electrode 0~80℃ Temp. Resistance For Dirty Water

Ask Latest Price
Video Channel
Brand Name :Daruifuno
Model Number :ASP200-VYD05
Certification :CE, ISO
Place of Origin :China
MOQ :1
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :10000 Sets per Month
Delivery Time :5-15 days
Packaging Details :Carton
Product Name :PH sensor
PH :0~14pH 0.01pH
Working Temperature :0.0~80.0℃
Reference System :Double salt bridge
Electrolyte :Gel
Working Pressure :0~2Bar
Temperature Unit :Vacant
Membrane :Porous
Glass Head :Transparent low impedance
Dimension :Diameter:12mm Length:120mm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Protection Bottle Glass PH Electrode 0~80℃ Temp. Resistance For Dirty Water

There are several reasons for measuring pH:
• Manufacture of stable products – During production, pH regulation is critical to ensure that the desired product is obtained. The pH value can significantly change the character and taste of the final product.
• Reduced production costs – this is related to the reasons above. If at a particular pH, the highest yield can be achieved, of course the cost of production will naturally be saved.
• Reduced hazards to humans, assets and the environment – ​​Some products are hazardous at certain pH levels. To protect people and assets, we strictly control the release of hazardous substances into the environment. The first step in determining whether a substance is hazardous is to measure its pH.
• Meet regulatory requirements – As noted above, some products are hazardous. Government agencies formulate corresponding management regulations to protect people from dangerous substances.
• Protect equipment and facilities – Some production equipment on the production line is in direct contact with the reactants, and if the pH value is not properly controlled, it will cause equipment corrosion. Therefore, in order to avoid the shortening of the life of the production line caused by corrosion, we should monitor the pH.
• Conducting R&D – During R&D, such as studying biochemical processes, pH is a very important reference parameter that often affects the outcome of the final study.
• The above examples illustrate the importance of pH in various applications and explain why pH needs to be measured.

Specification:

Product Name pH sensor
Product Model ASP200-VYD05
pH Range 0~14pH
Resolution 0.01pH
Shaft Material Glass
Working TEMP 0~80℃
Reference System double salt bridge
Reference Electrode Ag/AgCl
Electrolyte Gel
Working Pressure 0~2Bar
Temperature Unit Vacant/NTC10K /PT1000(optional)
Membrane Porous
Glass Head Transparent low impedance
Dimension Diameter: 12mm Length:120mm
Thread Size PG13.5
Lead Wire Standard 5m
Ground ——
Cleaning ——
Application

Dirty water

Please click the catalog of pH controller here:

Daruifuno Catalog.pdf

Brief introduction:

  • The glass head of the pH probe sensor is low-impedance hemispherical. It has high strength and does not break easily, it helps enhance the accuracy of measurement.
  • The reference electrode of the pH probe sensor is Ag/AgCl, filled KCL colorless high-temperature gel. The gel electrode is an upgraded and improved version of the liquid electrode that is low maintenance and suitable for online measurements in demanding applications and can last long after several cleanings and disinfection.
  • A porous diaphragm has the characteristics of fast penetration, fast response, not easy to block, and easy cleaning.
  • A mounting thread of size PG13.5 is provided at the end of the electrode for easier installation.
  • The pH probe is equipped with standard 5m low noise leads.

Protection Bottle Glass PH Electrode 0~80℃ Temp. Resistance For Dirty Water

Aplication:

Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

FAQ

1. What is themeasurement principle of this pH electrode?
A:
The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


2. How is this glass pH electrode composed?
A:
The pH electrode is usually composed of an indicator electrode and a reference electrode.


3. How to judge the pH of the solution?
A:
If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7;

if the two are the same, the solution is neutral and the pH value is equal to 7;

if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.


4. What is the wire length of the pH electrode?
A:
The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

5. How often must the pH sensor be calibrated?

A: Depends on the type of sample:Dirty samples and non-aqueous samples require more frequent calibration. Depends on the required accuracy: For very accurate measurements, at least daily calibration is required. Depends on the quality of the electrode: Old electrodes require more frequent calibration.

Inquiry Cart 0