RS485 Modbus MODBUS RTU Single Channel Digital Intelligent PH/ ORP Controller

Ask Latest Price
Video Channel
Brand Name :Daruifuno
Model Number :DUC2-A1-PH
Certification :ISO, CE
Place of Origin :China
MOQ :Negotiable
Price :Negotiable
Delivery Time :1-30days
Item name :PH/ORP controller
Detection channel :single digital channel input
Display screen :3.2-inch LCD display
Instrument operation :PET button panel, 8 buttons
System language :English (support customization)
Power-off protection :With
Historical data :Can record 10,000 historical data
Calibration log :records the last 100 times
Menu password :six-digit password setting
Relay output :2 configurable SPST relays
Setting objects :including high/low alarm, water temperature or wash control
Current output :1 channel 0/4~20mA
communication interface :RS485 interface MODBUS RTU
Protection grade :IP66
Operating environment :0~60℃
Storage environment :20~70℃
Instrument dimensions :100*100*120mm
Installation hole size :92*92mm
Installation method :cabinet panel installation
Shell Material :Reinforced ABS
Power requirements :AC: 100~240V, 50~60Hz; DC: +18~36V
Maximum power :7W
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

RS485 Modbus MODBUS RTU Single Channel Digital Intelligent PH/ ORP Controller

The single-channel digital intelligent controller of the DUC1 series is a small, compact and lightweight design, which is suitable for the panel installation of the cabinet.

The instrument is connected to and controls other equipment through a relay, and can also use 4~20mA current signal or RS485 digital signal to transmit instrument information.

Product Parameters

Instrument information/model

Online single channel intelligent controller DUC2-A1-PH

Detection channel

specified digital sensor

single channel input

Display screen

3.2-inch black and white graphic LCD display, pixel 128*64 dot matrix LCD

Instrument operation

PET button panel

8 buttons

System language

support customization

English

Power-off protection

the instrument is powered off, and the set data is permanently retained

Historical data

It can record 10,000 historical data, support historical data download,

and the recording interval can be set between 1 and 999 minutes

Calibration log records the last 100 times

Menu password

management of operation rights, six-digit password setting

Relay output

2 settable SPST relays, maximum load 3A/250VAC

2ways

Setting objects: including high/low alarm, water temperature or wash control

Current output

0/4~20mA can be set active current loop, load 1000 ohm, support long-term calibration

1 channel

Digital communication

communication interface: two-wire RS485 interface

1个

Communication protocol: MODBUS RTU

Protection grade

Dustproof and waterproof grade

IP66

Operating environment

0~60℃, relative humidity less than 95%RH (no condensation)

Storage environment

20~70℃, relative humidity less than 55%RH (no condensation, precision instrument)

Instrument dimensions

mm 100*100*120

Installation hole size

mm 92*92

Installation method

cabinet panel installation

Shell Material

Reinforced ABS

Electrical interface

3 M12*1.5 Glenn heads, wire diameter 3~6.5mm

Power requirements

AC:100~240V,50~60Hz;DC:+18~36V

AC and DC optional

Maximum power

7W

Instrument weight

700g

RS485 Modbus MODBUS RTU Single Channel Digital Intelligent PH/ ORP Controller

Brief introduction:

● Compatible with all DRFN digital pH sensors;
● Separately have a list of controller and sensor settings for quick and detailed parameter setting;
● The working status of the sensor can be queried, including reading the serial number;
● Support a variety of installation methods;
● Time and historical data recording function;
● 3.2-inch large LCD screen;
● User-friendly English language interface;
● Password can be set to prevent misoperation;
● 2 SPST multi-function and settable relays;
● Two way 0/4~20mA active current loop outputs;
● RS485 interface, Modbus RTU communication protocol;
● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;

The meter has a self-diagnostic function.

It can diagnose the PH/ORP sensor during calibration and maintenance. If the operation is improper or the PH/ORP sensor has poor characteristics, the screen will display the image and the buzzer will prompt briefly. It is recommended that the user re-maintain or replace the sensor.

The ORP PH controller can not only compensate the temperature of the test sample by connecting the temperature sensor, but also self-check the working temperature of the instrument in real-time. When the working temperature of the instrument changes, the instrument will compensate for the hardware changes caused by the temperature drift accordingly, making the detection result more accurate, this is a patented technology of daruifuno.

Aplication:
◇ Surface water
◇ Source water
◇ Aquaculture waters
◇ Landscape water
◇ Import of the waterworks

Water treatment monitoring

Drinking water,

◇ Groundwater, swimming pool

Industrial process monitoring and dosing control management

Chemical, petroleum, paper, food and medicine, electroplating, PCB manufacturing, etc.

FAQ
1. How many relays the controller with?

2 settable SPST relays, maximum load 3A/250VAC

Setting objects: including high/low alarm, water temperature or wash control

2. How many Current output the controller with?

One way 0/4~20mA can be set active current loop, load 1000 ohm, support long-term calibration