The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Ask Latest Price
Video Channel
Brand Name :Daruifuno
Model Number :OZ10.1
Certification :CE, ISO
Place of Origin :China
MOQ :Negotiable
Price :Negotiable
Payment Terms :T/T
Delivery Time :1-45 work days
Packaging Details :carton
Product Name :Chlorine dioxide sensor
Product Model :OZ10.1
Measuring range :0~0.5/2/5/10/20ppm
Pressure Range :0 ~ 1bar (Flow cell)
Temperature Range :0 ~ 45 ℃
Response Time :T90: approx. 3 min. (brine approx. 5 min.)
Flow Rate :15-30 l/h (33 – 66 cm/s)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Water treatment effect monitoring: Ozone is a strong oxidant widely used in water treatment processes, especially in drinking water, industrial water, wastewater treatment, etc. Ozone can effectively kill pathogenic microorganisms in water, such as bacteria, viruses and algae, and can oxidize organic pollutants, odor substances and color in water. Therefore, monitoring the ozone concentration in water helps to ensure the effect of water treatment.

Safety and health considerations: Although ozone has a significant improvement effect on water quality, high concentrations of ozone itself may be harmful to human health and the environment. Excessive ozone concentration in water may be toxic to the human body, especially if ozone is left in drinking water. Therefore, monitoring ozone concentration can ensure that it is within a safe range and prevent excessive residue.

Ozone consumption rate monitoring: During water treatment, ozone consumption will be affected by water quality, such as organic matter, ammonia nitrogen or other chemicals in water. By monitoring the ozone concentration in water, the consumption of ozone can be evaluated, and the dosage can be adjusted to ensure the effective use of ozone and avoid waste.

Environmental regulation: Ozone is an important disinfectant in the water treatment process, especially in areas with strict environmental protection requirements. Monitoring the ozone concentration in water can ensure compliance with regulations and environmental protection standards. For example, the US EPA and other regulatory agencies sometimes require monitoring of ozone residuals to ensure its disinfection effect on water quality and avoid negative impacts on the ecological environment.

Water treatment technology optimization: By regularly testing the ozone concentration in water, the operation of the water treatment system can be optimized, and the ozone addition and contact time can be improved, thereby improving disinfection efficiency and reducing operating costs. Monitoring data can help identify potential problems or optimize system configuration.

The two-electrode system amperometric ozone sensor 10.1, used for all water treatment, including seawater. Such as tap water, deionized water, RO-reverse osmosis membrane system has mechanical resistance, and the membrane system has strong resistance to surfactants.

The functional characteristics of the ampere film ozone sensor include high sensitivity and fast response, which can accurately measure the ozone concentration in water. Its advantages are strong anti-interference ability, suitable for various water quality environments, and long service life. It is suitable for drinking water and industrial water treatment to ensure water quality safety.

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Specifications

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

OZ10.1

Indicator Ozone
Application

All kinds of water treatment, also sea water, e. g.

  • Tap water
  • Deionised water
  • RO-water

The membrane system is mechanical resistant.
The membrane system is highly resistant to surfactants (tensides).

Measuring system Membrane covered, amperometric 2-electrode system

Electronic

Analog version: - voltage output

- not galvanically isolated electronics

- analog internal data processing

- output signal: analog (analog-out/analog)

Digital version: - electronic is completely galvanically isolated

- digital internal data processing

- output signal: analog (analog-out/digital)

or

digital (digital-out/digital)

mA-version: - current output analog

- not galvanically isolated electronics

- output signal: analog (analog-out/analog)

Information about the

measuring range

The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

Note: With a slope > 100% the measuring range is reduced accordingly.

(Ex.: 150% slope → 67% of the specified measuring range)

Accuracy
after calibration at repeatability
conditions (15°C, pH 7.2 in
drinking water) of the upper full
scale
-Measuring range 2 mg/l: at 0.4 mg/l <1%
at 1.6 mg/l <3%
- Measuring range 20 mg/l: at 4 mg/l <1%
at 16 mg/l <2%
Limit of detection -Measuring range 2 mg/l: 0.02 ppm

Working temperature

Measuring water temperature: 0 … +45 °C

(no ice crystals in measuring water)

Ambient temperature: 0 … +55 °C

Temperature

compensation

Automatically, by an integrated temperature sensor
Response time t90 = approx. 8 min.
Sudden temperature changes must be avoided

Max. allowed working pressure

Operation without retaining ring:

- 0.5 bar

- no pressure impulses and/or vibrations

Operation with retaining ring in Flow cell:

- 1.0 bar,

- no pressure impulses and/or vibrations (see option 1)

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

OZ10.1

Flow rate

(Incoming flow velocity)

Approx. 15-30 l/h (33 – 66 cm/s) in flow FLC, small flow rate dependence is given
pH-range pH 4 – pH 9
Run-in time First start-up approx. 1 h
Response time T90 : approx. 8 min.
Zero point adjustment Not necessary
Calibration At the device, by analytical determination, e. g. DPD-4 method (DPD-1 + DPD-3)
Advice: when used in sea water DPD-4 method (DPD-1 + DPD-3) is not
selective to ozone
Interferences

Cl2: OZ10.1H: factor 0.015
OZ10.1N: negligible
ClO2: OZ10.1N: factor 0.06

Absence of the disinfectant Max. 24 h

Connection

mV version:

Modbus version:

4-20 mA version:

5-pole M12, plug-on flange

5-pole M12, plug-on flange

2-pole terminal

or

5-pole M12, plug-on flange

max. length of sensor cable (depending on internal signal processing) analog < 30 m
digital

> 30 m are permissible

Maximum cable length depends on application

Protection type

5-pole M12 plug-on flange: IP68

2-pole terminal with mA-hood: IP65

Material Elastomer membrane, PVC-U, stainless steel 1.4571

Size

Diameter:

Length: mV version

Modbus version 4-20 mA version

approx. 25 mm

approx. 190 mm (analog signal processing)

approx.. 205 mm (digital signal processing)

approx. 205 mm

approx. 220 mm (2-pole-terminal)

approx. 190 mm (5-pole-M12)

Transport +5 … +50 °C (sensor, electrolyte, membrane cap)

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

OZ10.1

Storage

Sensor: dry and without electrolyte no limit at +5 … +40 °C

Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min. 1

year or until specified EXP-Date

Membrane cap: in original packing no limit at +5 … +40 °C

(used membrane caps can not be stored)

Maintenance

Regularly control of the measuring signal, min. once a week

The following specifications depend on the water quality:

Change of the membrane cap: once a year (depending on the water quality)

Change of the electrolyte: every 3 - 6 months

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Option 1:

Retaining ring

- When operating with pressures >0.5 bar in flow cell

- Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

- Different positions for groove selectable(on request)

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Technical Data

1. OZ10.1 (Analog output, analog internal signal processing)
A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Measuring range

in ppm

Resolution

in ppm

Output

Output

resistance

Nominal

slope

in mV/ppm

Voltage

supply

Connection
OZ10.1H-M12 0.005…2.000 0.001

0…-2000 mV

1 kΩ

- 1000

±5 - ±15 VDC

10 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: -U

PIN4: signal GND

PIN5: n. c.

OZ10.1N-M12 0.05…20.00 0.01 - 100
OZ10.1HUp-M12 0.005…2.000 0.001

0…+2000 mV

1 kΩ

+1000

10 - 30 VDC

10 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

OZ10.1Up-M12 0.05…20.00 0.01 +100

(Subject to technical changes!)

2. OZ10.1 (analog output, digital internal signal processing)
analog-out / digital
- The power supply is galvanically isolated inside of the sensor.
- The output signal is galvanically isolated too, that means potential-free.

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Measuring

range

in ppm

Resolution

in ppm

Output

Output resistance

Nominal

Slope

in mV/ppm

Power supply Connection
OZ10.1H-An-M12 0.005…2.000 0.001

analog

0…-2 V

(max. -2.5 V)

1 kΩ

- 1000

9-30 VDC

approx. 20-56 mA

5-pole M12 plug-on

flange

Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

OZ10.1N-An-M12 0.05…20.00 0.01 - 100
OZ10.1H-Ap-M12 0.005…2.000 0.001

analog

0…+2 V

(max. +2.5 V)

1 kΩ

+1000
OZ10.1N-Ap-M12 0.05…20.00 0.01 +100

(Subject to technical changes!)

3. OZ10.1 (digital output, digital signal processing)
-The power supply is galvanically isolated inside of the sensor.
-The output signal is galvanically isolated too, that means potential-free.

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Measuring

range

in ppm

Resolution

in ppm

Output

Output resistance

Power supply Connection
OZ10.1H-M0c 0.005…2.000 0.001

Modbus RTU

There are no terminating resistors in the sensor.

9-30 VDC

approx. 20-56 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: reserved

PIN2: +U

PIN3: power GND

PIN4: RS485B

PIN5: RS485A

OZ10.1N-M0c 0.05…20.00 0.01

(Subject to technical changes!)

4. OZ10.1 4-20 mA (analog output, analog internal signal processing)
A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.
4.1 Electrical connection: 2 pole terminal clamp

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Measuring

range

in ppm

Resolutio n

in ppm

Output

Output

resistance

Nominal

slope

in mA/ppm

Voltage

supply

Connection
OZ10.1MA0.5 0.005…0.500 0.001

4…20 mA

uncalibrated

32.0

12…30 VDC

RL 50Ω…RL 900Ω

2-pole terminal

(2 x 1 mm²)

Recommended:

Round cable

4 mm

2 x 0.34 mm²

OZ10.1MA2 0.005…2.000 0.001 8.0
OZ10.1MA5 0.05…5.00 0.01 3.2
OZ10.1MA10 0.05…10.00 0.01 1.6
OZ10.1MA20 0.05…20.00 0.01 0.8

(Subject to technical changes!)

4.2 Electrical connection: 5 pole M12 plug-on flange

The Two-Electrode System Amperometric Ozone Sensor Is Used For All Water Treatment

Measuring

range

in ppm

Resolution

in ppm

Output

Output

resistance

Nominal

slope

in mA/ppm

Voltage

supply

Connection
OZ10.1MA0.5-M12 0.005…0.500 0.001

4…20 mA

uncalibrated

32.0

12…30 VDC

RL 50Ω…RL 900Ω

5-pole M12

plug- on flange

Function of wires:

PIN1: n. c.

PIN2: +U

PIN3: -U

PIN4: n c.

PIN5: n. c.

OZ10.1MA2-M12 0.005…2.000 0.001 8.0
OZ10.1MA5-M12 0.05…5.00 0.01 3.2
OZ10.1MA10-M12 0.05…10.00 0.01 1.6
OZ10.1MA20-M12 0.05…20.00 0.01 0.8

(Subject to technical changes!)

Spare Parts

Type Membrane cap Electrolyte Emery O-ring
For all OZ10.1

M10.3N
Art. no. 11057

EOZ7/W, 100 ml
Art. no. 11102

S2
Art. no. 11906

20 x 1.5 silicone
Art. no. 11803

(Subject to technical changes!)